10-Minute Scissor Lift Pre-Use Inspection Checklist for Supervisors
A scissor lift pre-use inspection takes about 10 minutes, and OSHA requires one before every shift, according to an ISHN article by Braden Chupp of The Lift Bros, an Oklahoma aerial lift dealer and refurbisher. In construction, OSHA treats scissor lifts as mobile scaffolds under 29 CFR 1926.451 and 1926.452(w). A competent person must check for visible defects before each shift and after anything that could affect structural integrity.
The articleโs seven steps:
- Decals and manual: The manual must be on the machine, and the capacity, warning and control decals must be legible.
- Base walk: Look for hydraulic leaks, tire damage, tight battery terminals and correct charge, bent arms, missing pins or clips, and a damaged emergency lowering valve.
- Platform: Every guardrail must be pinned, and the gate must latch.
- Ground controls: Test raise, lower, emergency stop and emergency lowering.
- Platform controls: Test drive, steer, horn, tilt alarm, speed limiting and pothole protection.
- Work area: Check slopes, overhead hazards, wind limits and traffic. OSHA requires at least 10 feet from energized lines rated up to 50 kV.
- Paperwork: Log the inspection and tag out any failed machine.
What It Means for Subcontractors
- Start of shift: Build the 10 minutes into paid time at the start of every shift, and use the manufacturerโs checklist. The competent-person inspection applies to every shift and every machine, including rentals.
- Tag-outs: A failed lift, such as a fresh hydraulic puddle, a missing guardrail pin or a dead ground control, should be tagged out and reported the same day. The articleโs argument is that a day of downtime costs far less than a failure with someone on the platform. It cites no injury or cost figures.
- Power lines: Include the 10-foot clearance check from energized lines up to 50 kV in the pre-lift walk for any outdoor electrical or exterior work.